Solution-2 Specifications
- 26 I/O (expandable to 38):
- 7 initiation inputs (discreet or binary), dry contact or PNP
- 4 (expandable to 16 total) programmable115V valve outputs (24 VDC optional)
- 5 addressable proximity/pressure/limit switch inputs, dry contact or PNP
- EHR, End of Hold Relay (sequence completion), dry contact (NO or NC)
- INIT./REWELD reads binary code or repeats last weld, dry contact or PNP
- WATER SAVER 115V valve output (remains ON 1 minute after last weld
- 3 assignable FAULT outputs (MAJOR, MINOR, SPECIAL FAULT), dry contact or PNP
- ES, Emergency Stop input, dry contact or PNP
- NO WELD, external dry contact or PNP and also keypad selectable
- Transformer over temperature input, dry contact or PNP
- SCR over temperature input, dry contact or PNP
- Up to 45 LINKS (groups of functions) per CHAIN
- Up to 15 separate CHAINS (of 45 links each for a total of 675 LINKS)
- NO CODES TO LEARN, EVER!
- DOES NOT USE LADDER LOGIC PROGRAMMING or need a PC to program
- Uses simple 17 button keypad for all programming
- 70 complete RWMA weld program memory, does not require linking
- Ability to use the same weld PROGRAM at multiple locations in a CHAIN
- Can insert time delay and stop sequences at desired places in the CHAIN
- Full 32 character alpha/numeric readout in PLAIN ENGLISH – NO CODES
- Valve outputs 4 (expandable to 16 total) can be independently designated in programs to:
- Turn on or off at the start of any link
- Turn on or off at the end of any link
- Includes ANTI-TIEDOWN and ANTI-REPEAT functions
- Can be initiated in 5 different ways
- Single Stage switch closure to select any of 7 CHAINS
- Two Stage switch closure to select any of 3 CHAINS
- Binary switch input to directly select any of 70 programs
- Binary switch input to select any of 15 CHAINS
- Keypad Select non-chaining mode to select a single weld schedule of the 70 available
- One prox. input can be used for a LIGHT CURTAIN (preprogrammed function)
- Can control up to 15 SCR contactors in any sequence (Multi-SCR option)
- Can monitor Weld Current (option)
- Single primary CT
- Up to 15 secondary coils
- Can read up to 16 different Differential Pressure Transducers or Load Cells (option)
- Keyboard Keylock is standard
- Digital COUNTER displays individual welds or completed parts
- CHAINS can be manually or automatically run in 6 different modes:
- Run the CHAIN one time and stop
- Run the CHAINS sequentially
- Run the CHAIN one time. If a proximity switch is closed at the end, stop.
- Run as above – At the end, go to the next CHAIN
- Run a CHAIN 2-99 times and stop
- Run a CHAIN 2-99 times and go to the next CHAIN